Page: HUB Terminal Quadrants

Universal Safety Controller HUBâ„¢
Multiple Safety Devices...One Safety Controller!
Terminal Quadrants

Upper Left - 12 Position Connector

12 Position Connector
Upper Left

CAN Network /Solid State Status Outputs / Solid State Safety Outputs

Terminal 29

CAN L (Slave) Expansion HUB

Terminal 30

CAN H (Slave) Expansion HUB

Terminal 31

Status Output E-1 (1/2A Solid State, +24V or GND out)

Terminal 32

Status Output E-2 (1/2A Solid State, +24V or GND out)

Terminal 33

Status Output E-3 (1/2A Solid State, +24V or GND out)

Terminal 34

Status Output E-4 (1/2A Solid State, +24V or GND out)

Terminal 35

Status Output E-5 (1/2A Solid State, +24V or GND out)

Terminal 36

Status Output E-6 (1/2A Solid State, +24V or GND out)

Terminal 37

Status Output E-7 (1/2A Solid State, +24V or GND out)

Terminal 38

Status Output E-8 (1/2A Solid State, +24V or GND out)

Terminal 39

D-1 Safety Output (1/2A Solid State Safety Output) Monitored *

Terminal 40

D-2 Safety Output (1/2A Solid State Safety Output) Monitored *

*Must be wired to control reliable systems or our 52-278 captive contact safety relays. Higher Amp Output for Channel D also available.

 

Lower Left - 16 Position Connector

 

16 Position Connector
Lower Left

Power Input / Safety Relay Output / Auxiliary Relay

Terminal 1

Power Supply Input (+24vdc input)

Terminal 2

Power Supply Input (ground)

Terminal 3

Earth Ground

Terminal 4

C-1a Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored

Terminal 5

C-1b Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored

Terminal 6

C-2a Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored

Terminal 7

C-2b Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored

Terminal 8

C-3a Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored

Terminal 9

C-3b Safety Output (N.O. held closed) 8A@250vac (Dry) Monitored

Terminal 10

C-4a Auxiliary Output (N.O.) 5A@250vac (Dry)

Terminal 11

C-4b Auxiliary Output (C) 5A@250vac (Dry)

Terminal 12

C-4c Auxiliary Output (N.C.) 5A@250vac (Dry)

Terminal 13

Open

Terminal 14

Open

Terminal 15

+24vdc out (feed thru from Terminal #1)

Terminal 16

Ground out (feed thru from Terminal #2)



Upper Right - 12 Position Connector

 

12 Position Connector
Upper Right

Channel B / Safety or non-safety inputs B-1 to B-12

Terminal 41

Channel B-1 (pnp/npn input or signal output)

Terminal 42

Channel B-2 (pnp/npn input or signal output)

Terminal 43

Channel B-3 (pnp/npn input or signal output)

Terminal 44

Channel B-4 (pnp/npn input or signal output)

Terminal 45

Channel B-5 (pnp/npn input or signal output)

Terminal 46

Channel B-6 (pnp/npn input or signal output)

Terminal 47

Channel B-7 (pnp/npn input or signal output)

Terminal 48

Channel B-8 (pnp/npn input or signal output)

Terminal 49

Channel B-9 (pnp/npn input or signal output)

Terminal 50

Channel B-10 (pnp/npn input or signal output)

Terminal 51

Channel B-11 (Mat + IN) (pnp/npn input or signal output) Dedicated terminals 11 & 12 for

Terminal 52

Channel B-12 (Mat - IN) (pnp/npn input or signal output) powering control logic for Safety Mats, Edges and Bumpers.



Lower Right - 12 Position Connector

 

12 Position Connector
Lower Right

Channel A / Safety or non-safety inputs A-1 to A-12

Terminal 17

Channel A-1 (pnp/npn input or signal output)

Terminal 18

Channel A-2 (pnp/npn input or signal output)

Terminal 19

Channel A-3 (pnp/npn input or signal output)

Terminal 20

Channel A-4 (pnp/npn input or signal output)

Terminal 21

Channel A-5 (pnp/npn input or signal output)

Terminal 22

Channel A-6 (pnp/npn input or signal output)

Terminal 23

Channel A-7 (pnp/npn input or signal output)

Terminal 24

Channel A-8 (pnp/npn input or signal output)

Terminal 25

Channel A-9 (pnp/npn input or signal output)

Terminal 26

Channel A-10 (pnp/npn input or signal output)

Terminal 27

Channel A-11 (Mat + OUT) (pnp/npn input or signal output) Dedicated terminals 11 & 12 for

Terminal 28

Channel A-12 (Mat - OUT) (pnp/npn input or signal output) powering control logic for Safety  Mats, Edges and Bumpers.



View of HUB

 Print this page

Safety Light Curtains
   Safety Light Curtain Comparison
   Model SS Solid State Outputs Safety Light Curtain
   Model SS Product Overview
   Model SS Blanking Options
   Model SS Safety Relay
   Model SS Specs and Dimensions
   Model SS Ordering Procedure
   Model SS Accessories
   Model MG Metal Box Controller and Safety Light Curtain
   Model MG Product Overview
   Model MG Smart Controller
   Model MG Design Criteria
   Model MG Features
   Model MG Dimensions
   Model MG Blanking Options
   Model MG Ordering Procedure
   Model MG Accessories
   Model MG Ethernet Option
   Model DR DIN-rail Controller and Safety Light Curtain
   Model DR Product Overview
   Model DR Smart Controller
   Model DR Design Criteria
   Model DR Features
   Model DR Dimensions
   Model DR Blanking Options
   Model DR Ordering Procedure
   Model DR Accessories
   Model CE Solid State Outputs Global Safety Light Curtain
   Model CE Product Overview
   Model CE Blanking Options
   Model CE Safety Relay
   Model CE Specs and Dimensions
   Model CE Ordering Procedure
   Model CE Accessories
   Model CA Cascading Safety Light Curtain
   Model CA Product Overview
   Model CA Blanking Options
   Model CA Safety Relay
   Model CA Specs and Dimensions
   Model CA Ordering/Pricing Procedure
   Model CA Accessories
   Model PPG Perimeter Guarding
   Model PPG Product Overview
   Model PPG Dimensions
   Model PPG Ordering Procedure
   Model PPG Accessories
Safety Mat Systems
   NSD Safety Mat System
   NSD Product Overview
   NSD No Steel Electrodes?
   NSD Mat Controllers
   NSD Layout Procedure
   NSD Trim Kits
   NSD Ordering Procedure
   NSD Sizing Your System
   NSD Wiring Options
   NSD Safety Modules
   STTS Safety Mat System
   STTS Product Overview
   STTS Design Criteria
   STTS Mat Controllers
   STTS Controller Dimensions
   STTS Layout Procedure
   STTS Trim Kits
   STTS Ordering Procedure
   STTS Sizing Your System
   Direction of Travel Mats
   High-Temp Welding Mats
Ergonomic Palm Buttons
   UltraTouch Product Overview
   What can UltraTouch do for you?
   UltraTouch Benefits
   Ergonomic Palm Button Comparison
   UltraTouch Specifications
   UltraTouch Dimensions
   UltraTouch Models Available
   UltraTouch Ordering Procedure and Finding a Part Number
   UltraTouch Accessories
Programmable Safety Controller
Safety Interlock Switches
   GKM Series
   GKN Series
   GKE Series
   GK Series
   GKR/GKL Series
   GSS Series
   1CPS Series
   2CPS Series
   FF3-21-DC-03
   FF5-21-DC-03
   FF6-10-DC-03
   FFS-11-03
   BX Series
   GSX Series
   CLSX Series
   Stack Lights Product Overview
   Stack Lights Ordering Procedure
   Stack Lights Dimensions
   Stack Lights Specifications
   Stack Lights Wiring Diagrams
   Stack Lights Accessories
   Stack Lights Accessories Mounting Poles
   Stack Lights Accessories Mounting Bases
   Stack Lights Wall Accessories Mount Brackets
Fencing
   Fencing Overview
   Fencing Specifications
   Fencing Styles
   Complies with Safety Standards
   OSHA Table 0-10
   Fencing Warranty
   Proposal Request
E-Stops & Stack Lights
Metal Stamping / Pressroom Products
   Press Control Design Criteria
   Punch Press Clutch/Brake Controls
   Press Automation
   Die Protection
   Tonnage Monitoring
   Programmable Limit Switches
   Time-Based Brake Monitors
Safety Glossary
   Glossary A-C
   Glossary D-F
   Glossary G-I
   Glossary J-L
   Glossary M-O
   Glossary P-R
   Glossary S-U
   Glossary V-Z
Risk Assessment
Repair of Products
Corporate Profile
Standards and Regulations
   1910.211
   1910.212
   1910.213
   1910.216
   1910.217
   Appendix A
   Appendix B
   Appendix C
   Appendix D
   ISO and IEC Standards
   What Does OSHA Do?
   ANSI
   Domestic and International Standards Organizations
   OSHA Concept and Techniques of Machine Guarding

Home
Contact Our Sales Department
Contact Our Service Department