Model SS
Solid State Safety Light Curtain
Ordering/Pricing Procedure
|
Example Part
#
|
SS
|
04
|
OF
|
20
|
(Options)
|
|
|
Solid State
Outputs
|
Pylon Size
|
Light Curtain Style and Beam
Spacing
|
Scanning distance
in feet - 20' (6.1m) standard, 35' (10.7m)
maximum
|
|
Light
Curtain Model or Style SS - Solid State
Outputs
Pylon
Sizes (Protected Area in inches) 1/2” (13mm) Beam
Spacing:
04,08,12,16,20,24,28,32,36,40,44,48,52,56,60,64
1” (25mm) Beam Spacing:
04,08,12,16,20,24,28,32,36,40,44,48,52,56,60,64,68,72,76,
80,74,88,92,96,100,104,108,112,116,120
4” (102mm) Beam Spacing:
04,08,12,16,20,24,28,32,36,40,44,48,52,56,60,64
Light
Curtain Style and Beam
Spacing
1/2” (13mm) Spacing of
Beams OF -
Constant scan - no blanking.
1F - 1 beam floating blank
built-in.
8K - Up to 3 beam floating
blank adjustable by the use of a keyswitch removable in all
positions. Capable of constant scan or one, two, or three
floating beams. (Requires RSD option)
AB - Includes constant scan
light curtain, one beam floating blank, and two auto blank
modes. (Requires RSD option)
CE - No blanking, 24VDC input
power, 2° angle of divergence, and CE certified (designed
to conform to the European Market and worldwide IEC 61496
Parts 1 & 2 Standards).
1” ( 25mm) Spacing of
Beams OF1 -
Constant scan - no blanking.
1F1 - 1 beam floating blank
built-in.
8K1 - Up to 3 beam floating
blank adjustable by the use of a keyswitch removable in all
positions. Capable of constant scan or one, two, or three
floating beams. (Requires RSD option)
AB1 - Includes constant scan
light curtain, one beam floating blank, and two auto blank
modes. (Requires RSD option)
CE1 - No blanking, 24VDC input
power, 2° angle of divergence, and CE certified (designed
to conform to the European Market and worldwide IEC 61496
Parts 1 & 2 Standards).
4”
( 102mm) Spacing of Beams (no blanking options
available) OF4 - For perimeter
guarding, body detection. 4.25” (108mm) object sensitivity.
4” (102mm) active area followed by a 4” (102mm)
gap.
Options (Add underlined suffix
to part number) No Additional
Charge Options (add underlined suffix to part
number)
EDM
- External Device
Monitoring (EDM): Feature enabled requires the use of 2
external safety relays.
LR
- Resettable Latching
Relays: Requires the light curtain to be manually reset
every time the sensing field is
penetrated.
AVAILABLE ON THE MODEL
SS
RSD
- Model
SS Remote Status Display (RSD): Remote mounting plate
providing a single location to mount the following on
existing panel door: light curtain scrolling diagnostic
message display, blanking keyswitch (if applicable), and
status indicator lights (all styles).
AVAILABLE ON SOLID STATE
MODELS (SS)
SMB
- Swivel
Mounting Brackets for Pylons: Replaces the L-shaped fixed
mounting brackets normally supplied. Provides a 360°
rotation of pylons.
SSSR
-
Captive Contact Safety
Relay Module
Extended Range Units: 21’ (6.4m) to
50’ (15.24m) scanning distances (specify desired scanning
distance).
**Model SS Output Circuits must be used
with either
"Control Reliable" PLC Safety
Input Circuits or a Safety Relay Module.
**
|