| Dual
Redundancy Design Concept
The SLT Series
safety light curtain utilizes the dual redundancy design concept. This
gives the safety light system a high level of redundancy and control reliability.
Self-Checking Circuitry
The SLT Series safety light curtain self-checks every 20 milliseconds.
Self-checking is the ability to electronically verify that all of the
systems critical internal circuit components and their redundant
counterparts or back-ups are operating properly.
Extra Safe Design
Provides two methods of fail-safe design. One utilizes two microprocessors
and two captive contact relays, and one uses four watchdog timers monitoring
the system and the captive contact relays.
Redundant Captive Contact
Safety Relays
Redundant relays assure safety if an output relay should fail. The SLT
Series utilizes safety relays which have force-guided contacts. The contacts
are mechanically locked together so that if one set of contacts weld,
the other contacts cannot change state. If one should fault, a Code 5
or 6 will be displayed on the diagnostic display.
External Diagnostic Display
Standard on the SLT Series safety light curtain is the "Quickview
Diagnostic Displayan alphanumeric display showing status and
fault codes of the unit (an excellent safety and maintenance feature).
Control Reliable System
Critical components of the SLT Series are duplicated so that a single
component failure will not cause an unsafe condition. If a component does
fail, the units self-checking circuitry recognizes the situation
and initiates a safe stop of the machine.
Powerful Infrared Light
Source
The SLT Series utilizes powerful, safe, and predictable infrared light
as its sensing source. This gives the system greater reliability and enhances
machine utilization by minimizing nuisance trips and shutdowns caused
by dirt, coolants, lubrication mists, and machine oils. The SLT Series
is highly immune to EMI, RFI, ambient light conditions, and are unaffected
by strobe lights and weld flash generated light sources.
Extensive Testing
The SLT Series incorporates extensive testing and burn-in to establish
a high degree of product reliability and safety.
|