Machine Safety
Pinnacle SystemsMIcroGuard Safety Light CurtainSafety Light CurtainSafety Mat SystemPalm ButtonsContact Pinnacle Systems
Smart Controller | Design Criteria | Metal Box | DIN-Rail | Features | Dimensions | Blanking | Find a Part Number | Accessories
Pinnacle Systems, Inc.

MicroGuard Safety Light Curtain

ORDERING PROCEDURE

Example
Part #

MG
04
OF
20
(Options)
 
Light Curtain Module Housing
Pylon Size
Light Curtain Style and Beam Spacing
Scanning distance in feet - 20' (6.1m) standard, 50' (15.24m) maximum
   
 
Light Curtain Controller Module Housing

MG - NEMA 12 & 13 (IP64) stand alone Metal Box Controller Module with Safety Relays
DR - 35mm DIN-rail Mountable Safety Relays and Controller Module (24 VDC Input Power Only)

 

Pylon sizes (protected area in inches) with 1/2" (13mm) beam spacing:
04, 08, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Pylon sizes available (protected area) with 1" (25mm) beam spacing:
04, 08, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64, 68, 72, 76, 80, 84, 88, 92, 96, 100, 104, 108, 112, 116, 120

Light Curtain Style and Beam Spacing
  1/2" (13mm) Spacing of Beams  
   
OF
Constant Scan - No blanking.
 
1F
Has one beam floating blank built-in.
 
8K
Up to three beam floating blank (reduced resolution) adjustable by a locking key switch. Capable of constant scan or one, two or three floating beams.
   
AB
Includes constant scan light curtain, one beam floating blank and two auto blank modes.
   
CE
No blanking, 24VDC input power, 2o angle of divergence, and CE compliant. Designed to conform to the European market and worldwide IEC 61496 1 and 2 standards and CE.
  1" (25mm) Spacing of Beams        
   
OF1
Constant Scan - No blanking.
   
1F1
Has one beam floating blank built-in.
   
8K1
Up to three beam floating blank (reduced resolution) adjustable by a locking key switch. Capable of constant scan or one, two or three floating beams.
   
AB1
Includes constant scan light curtain, one beam floating blank, and two auto blank modes.
   
CE1
No blanking, 24VDC input power, 2o angle of divergence, and CE compliant. Designed to conform to the European market and worldwide IEC 61496 1 and 2 standards and CE.
   
 
Options (Add underlined suffix to part number)

Available on BOTH Metal Box and DIN-rail Controllers

  • SMB - Swivel Mounting Bracket for Pylons: Replaces the L-shaped fixed mounting brackets normally supplied. This option provides 360° rotation of pylons.
  • MO - Guarding Mute-Out: Mutes out light curtain on non-hazardous portion of machine cycle.
  • DN - DeviceNet™: Fieldbus network compatible. Add suffix DN to light curtain model number.
  • Extended Range Units: 21' (6.4m) to 50' (15.24m) scanning distances (specify desired scanning distance).

Available ONLY on the Metal Box Controller

  • DS - Dual Individual Stop Outputs
  • LR - Resettable Latching Relays (Metal Box Controller): Requires the light curtain to be manually reset each time the light curtain is penetrated.
  • SC - Single Controller for Multiple Light Curtain (Metal Box Controller):
    Cost effective approach when a machine requires multiple light curtains. The multiple light curtain systems are controlled by a single MicroGuard controller. Up to four sets of pylons can be connected to the controller. Add suffix SC to light curtain model number and additional plyon sizes.
  • ES - Emergency Stop Input. E-Stop input requiring the MicroGuard to issue a stop command (built in standard on the DIN-rail Safety Relay Controller Module).
  • 24VDC - 24 VDC Input Power (Metal Box Controller): Add suffix DC for 24 VDC input power.
  • 220VAC - 220 VAC Input Power (Metal Box Controller): Add suffix 220VAC for 220 VAC input power.

Available ONLY on the DIN-rail Controller

  • RSD - Remote Status Display (DIN-rail Controller):
    Remote mounting plate that provides the Diagnostic Scrolling Message Display, Blanking Key Switch Control (if applicable), Status Indicatory Lights, and Reset Button. Add suffix RSD to light curtain model number.
  • CI - Cincinnati Interface (DIN-rail Controller):
    Requires the MicroGuard DIN-rail to issue a stop command every cycle. Add suffix CI to light curtain model number.
  • AO - Analog Output for Non-Safety Applications: -10VDC to +10VDC or )VDC to +10VDC

Extra Pylon Protection (optional)

  • PT - Polycarbonate Tube: Encases the pylons for high impact protection.
  • AT - Acrylic Tube: Encases the pylons for protection from caustic and/or chemical agents.


American Express, Visa & Mastercard Accepted!

Home | Return to MicroGuard Introduction | Safety Light Curtains | Safety Mat Systems | Ergonomic Palm Buttons | Contact Us
Additional Information & Resources:
For detailed technical information on the MicroGuard® Safety Light Curtain and other Pinnacle Systems safety products download Installation Manuals.

To speak to a sales representative in the United States, please call (800) 569-7697.

Request a catalog or price quote online or send an e-mail.

All products are manufactured to meet or exceed all applicable OSHA and ANSI standards and are made in the U.S.A.

You are Finding a MicroGuard® Part Number
For more MicroGuard® Safety Light Curtain information, choose from the following:

Pinnacle products are Made in the USA

Smart Controller
Design Criteria
Metal Box Controller
DIN-Rail Controller
MicroGuard® Features
Dimensions
Blanking Options
Accessories

MicroGuard Brochure Cover
Download our PDF
MicroGuard® Brochure